Technical Specifications:
Volume based irrigation device, consisting of a water meter, a volume
control dial and a valve all contained in a single unit.
Performance:
Minimum Flow Rate 0.5 m3/h - [2.2 GPM]
Maximum Flow Rate 5.0 m3/h - [22 GPM]
Minimum Working Pressure 0.5 (bar) - [7.5 PSI]
Maximum Working Pressure 10.0 (bar - [145 PSI]
Maximum Working Temperature 60°C - [140° F]
Dimensions:
Length 200mm Width 90mm Height 115mm Weight 0.55 Kg.
Dose-O-Mat, arad model K, operation instructions, Start-Up Operation. NOTE: There must be available flow through the Dos-O-Mat valve and system to check and adjust valve. Insure that a downstream demand is created by opening field valves, sprinklers, etc. Please verify that the unit is installed according to the flow direction ! (arrow on the top body). |
1. Close main valve by fully turning setting knob (1) on top of the valve counter-clockwise until dial face is on zero exactly in front of the body arrow (2) and clicks.
2. Open fully the upstream gate valve but open gate the downstream gate valve only slightly (if applicable). Main valve should remain closed.
3. Slowly turn setting knob (1) on top of the valve. Turn it counter-clockwise to the desired volume on the dial face aligning the desired volume with arrow (2) on the valve body.
4. Open the downstream gate valve fully (if applicable) and valve should open completely for normal Operation. |
 |
1" Dose O Mat unit packaging information:
Weight: 0.77 Kg.
Box dimensions: 24x13x13 CM